Troubleshooting Guide

How to Fix Dingli BT26RT Fault Code 26

Left Axle Lock Feedback Error (Power Off)

Error Code: 26Equipment: Boom Lift

Error Code 26 Diagnosis

What This Code Means

Left Axle Lock Feedback Error (Power Off)

Recommended Solution

Check left floating cylinder solenoid valve wiring. Inspect valve block for stuck solenoid. Verify hydraulic supply to axle lock circuit. Replace left floating valve block or controller.

Verified Technical Content

This troubleshooting guide has been reviewed and verified by the China Lift Supply Technical Team. Our certified technicians specialize in Dingli equipment diagnostics and maintain accuracy based on official service documentation.

Reviewed by Christopher Ray, Technical Director

Parts & Tools You May Need

Based on this error code, these items may help with your repair

Battery Charger

Part

Industrial-grade lithium battery charger for electric forklifts

View Options

Need Parts to Fix This?

Common replacement parts for the BT26RT

Drive/Steer Joystick

DL-00005393

Platform Function Joystick

DL-00005394

Tilt Sensor

00010633

Toggle Switch (Function Enable)

00006134
Dingli BT26RTDingli

BT26RT

Dingli Boom Lift

Machine Specs

EngineDeutz TD2.9 L4 / 55.4kW
Gradeability45%
Gross Weight16,090kg (35,472lb)
Power SourceDiesel
View Full BT26RT Page

Can't Fix It?

Our technical team specializes in Dingli equipment diagnostics.

Why Trust This Guide?

  • Based on official Dingli service documentation
  • Verified by certified equipment technicians
  • Updated with latest service bulletins

Keep Your BT26RT Running Smoothly

ChinaLiftSupply stocks genuine and aftermarket parts for all Dingli equipment. Get expert support and fast shipping on every order.