Troubleshooting Guide

How to Fix Dingli BT26RT Fault Code 03

Ground Controller MC2M System Error

Error Code: 03Equipment: Boom Lift

Error Code 03 Diagnosis

What This Code Means

Ground Controller MC2M System Error

Recommended Solution

Check controller harness connections. Verify 12V power supply to controller. Inspect CAN bus termination resistors. Replace ground controller if fault cannot be cleared.

Need Parts to Fix This?

Common replacement parts for the BT26RT

Drive/Steer Joystick

DL-00005393

Platform Function Joystick

DL-00005394

Tilt Sensor

00010633

Toggle Switch (Function Enable)

00006134