Troubleshooting Guide
How to Fix Dingli BA28RT Fault Code 01
Ground Controller MC2M Hardware Fault
Error Code: 01Equipment: Boom Lift
Error Code 01 Diagnosis
What This Code Means
Ground Controller MC2M Hardware Fault
Recommended Solution
Try to restart the power supply. Check the external wiring and power supply of the controller. Measure voltage between S1 and S21 pins (should be ~12V). Measure bus resistance between S23 and S25 pins (should be 60-120Ω). Replace ground controller if fault persists.
Verified Technical Content
This troubleshooting guide has been reviewed and verified by the China Lift Supply Technical Team. Our certified technicians specialize in Dingli equipment diagnostics and maintain accuracy based on official service documentation.
Reviewed by Christopher Ray, Technical Director
Parts & Tools You May Need
Based on this error code, these items may help with your repair
Digital Multimeter
ToolEssential for diagnosing voltage and current issues
Motor Controller
PartAC/DC motor controller for electric lift equipment
Popular Dingli Troubleshooting
DingliBA28RT
Dingli Boom Lift
Machine Specs
EngineDeutz TD2.9 L4 / 55.4kW
Gradeability45%
Gross Weight18,400kg (40,565lb)
Power SourceDiesel
Why Trust This Guide?
- Based on official Dingli service documentation
- Verified by certified equipment technicians
- Updated with latest service bulletins