How to Fix Dingli BA28RT Fault Code 06

Platform Controller MC2M Communication Error

Error Code: 06Equipment: Boom Lift

Error Code 06 Diagnosis

What This Code Means

Platform Controller MC2M Communication Error

Recommended Solution

Check platform controller CAN bus wiring. Verify harness connections through boom and turret. Inspect slip ring connections for continuity. Replace platform controller if fault persists.
Dingli BA28RTDingli

BA28RT

Dingli Boom Lift

Machine Specs

EngineDeutz TD2.9 L4 / 55.4kW
Gradeability45%
Gross Weight18,400kg (40,565lb)
Power SourceDiesel