Troubleshooting Guide

How to Fix Dingli JCPT1912DC Fault Code 153

Scissor Angle Channel B Open/GND

Error Code: 153Equipment: Scissor Lift

Error Code 153 Diagnosis

What This Code Means

Scissor Angle Channel B Open/GND

Possible Causes

  • 1Scissor angle sensor channel B - open circuit or shorted to ground

Recommended Solution

Inspect angle sensor channel B wiring. Check for damaged cables.
Dingli JCPT1912DCDingli

JCPT1912DC

Dingli Scissor Lift

Machine Specs

Power SourceElectric (48V)
Lift Capacity750kg
Platform Size4.30m × 1.19m
Working Height19.00m
View Full JCPT1912DC Page