Troubleshooting Guide

How to Fix Dingli JCPT1612HD Fault Code 149

Scissor Angle Channel A Open/GND

Error Code: 149Equipment: Scissor Lift

Error Code 149 Diagnosis

What This Code Means

Scissor Angle Channel A Open/GND

Possible Causes

  • 1Scissor angle sensor channel A - open circuit or shorted to ground

Recommended Solution

Inspect angle sensor wiring. Check for damaged cables or loose connections.
Dingli JCPT1612HDDingli

JCPT1612HD

Dingli Scissor Lift

Machine Specs

Power SourceElectric
Lift Capacity200kg
Platform Size2.64m × 1.12m
Working Height15.70m
View Full JCPT1612HD Page