Troubleshooting Guide

How to Fix Dingli JCPT0607A Fault Code 225

TM1 High Temp PCB

Error Code: 225Equipment: Scissor Lift

Error Code 225 Diagnosis

What This Code Means

TM1 High Temp PCB

Possible Causes

  • 1TM1 controller circuit board overheating

Recommended Solution

Stop operation, allow cooling. Check ventilation. Reduce duty cycle. Clean dust from electronics.

Need Parts to Fix This?

Common replacement parts for the JCPT0607A

Joystick Controller

DL-00002324

Platform Control Box

00004632

Battery Charger 24V 15A

DL-00002380

PCU Module Assembly

00000706
Dingli JCPT0607ADingli

JCPT0607A

Dingli Scissor Lift

Machine Specs

Power SourceElectric
Lift Capacity240kg
Platform Size1.29m × 0.70m
Working Height5.90m
View Full JCPT0607A Page

Can't Fix It?

Our technical team specializes in Dingli equipment diagnostics.

Why Trust This Guide?

  • Based on official Dingli service documentation
  • Verified by certified equipment technicians
  • Updated with latest service bulletins

Keep Your JCPT0607A Running Smoothly

ChinaLiftSupply stocks genuine and aftermarket parts for all Dingli equipment. Get expert support and fast shipping on every order.