Troubleshooting Guide

How to Fix Dingli JCPT0607A Fault Code 210

TM1 Power Supply Out of Limit

Error Code: 210Equipment: Scissor Lift

Error Code 210 Diagnosis

What This Code Means

TM1 Power Supply Out of Limit

Possible Causes

  • 1Traction motor power supply voltage out of acceptable range

Recommended Solution

Check battery voltage and connections. Verify charger operation. Battery may need replacement.

Need Parts to Fix This?

Common replacement parts for the JCPT0607A

Joystick Controller

DL-00002324

Platform Control Box

00004632

Battery Charger 24V 15A

DL-00002380

PCU Module Assembly

00000706
Dingli JCPT0607ADingli

JCPT0607A

Dingli Scissor Lift

Machine Specs

Power SourceElectric
Lift Capacity240kg
Platform Size1.29m × 0.70m
Working Height5.90m
View Full JCPT0607A Page

Can't Fix It?

Our technical team specializes in Dingli equipment diagnostics.

Why Trust This Guide?

  • Based on official Dingli service documentation
  • Verified by certified equipment technicians
  • Updated with latest service bulletins