Troubleshooting Guide
How to Fix LGMG SR1218D Fault Code 09
Invalid Pedal/Joystick Alarm
Error Code: 09Equipment: Scissor Lift
Error Code 09 Diagnosis
What This Code Means
Invalid Pedal/Joystick Alarm
Recommended Solution
Release the pedal switch. Check pedal harness connection status for short-circuit or open-circuit. Replace joystick if signal is invalid at neutral.