LGMG AS1012EScissor Lift
Product Overview
The LGMG AS1012E (also known as AS3246E) is a 32ft electric scissor lift delivering maximum indoor working height for rental fleets. The wider 46-inch platform with increased 705lb capacity accommodates heavier tool loads and multiple workers for large-scale interior projects. Parts commonality with other LGMG electric scissors simplifies inventory management and technician training across rental fleet operations. The intelligent self-diagnostic system provides fault codes for quick troubleshooting, critical for minimizing rental downtime. Direct electric drive technology delivers reliable performance with lower maintenance requirements than hydraulic systems.
Key Features
- 32ft Working Height - Indoor Maximum
- 705lb Platform Capacity for Heavy Loads
- Universal Parts Across LGMG E-Series
Technical Specifications
| Specification | Value |
|---|---|
| Drive Mode | 4x2 |
| Gradeability | 25% |
| Power Source | 24V DC 240Ah Electric |
| Overall Width | 1.2m (3ft 11in) |
| Platform Size | 2.26m x 1.12m (7ft 5in x 3ft 8in) |
| Extension Deck | 0.9m (3ft) |
| Machine Weight | 2,750kg (6,063lbs) |
| Working Height | 12m (39.4ft) |
| Platform Height | 10m (32.8ft) |
| Platform Capacity | 320kg (705lbs) |
Available Parts
Need Parts for AS1012E?
We have direct access to the complete LGMG parts catalog. Tell us what you need and we'll source it at competitive prices.
Customer Reviews
No reviews yet for the LGMG AS1012E. Operated or serviced one? Be the first to share how it holds up.
Fault Codes & Troubleshooting
Search for error codes displayed on your AS1012E to find causes and solutions. Click on any code to expand details.
| Code | Description | Expand |
|---|---|---|
| 01 | System Initialization Error | |
| 02 | System Communication Error | |
| 03 | Model/Machine Code Error | |
| 05 | ECU and BMS Communication Failure | |
| 09 | Invalid Pedal/Joystick Alarm | |
| 14 | Motor Controller 1 Communication Failure | |
| 16 | BMS Fault (Battery Management System) | |
| 18 | Pothole Protection Error | |
| 27 | Down Proportional Valve Fault | |
| 31 | Pressure Sensor Error | |
| 32 | Angle Sensor Error | |
| 36 | Low Battery Alarm | |
| 60 | Motor Controller Fault (General) | |
| 68 | Low Voltage Fault | |
| 71 | Motor Controller Contactor Fault | |
| 73 | Motor Controller Overheated | |
| 80 | Exceeding 80% Load Warning | |
| 90 | Exceeding 90% Load Warning | |
| LL | Tilt/Level Sensor Alarm (Machine Tilted) | |
| OL | Platform Overload Alarm |